Wall mount solar charger power inverter 5kw
Product Description
1,AC/Solar charging hybird off grid inverter;
2,LED/LCD display,Enhanced functions setting via LCD,Man-machine intelligent design;
3,Built-in 40A/60A optional MPPT solar charge controller;
4,Remote external dispaly panel realize remote operation;
5,Five stages adjustable AC charging current,AC charging also can be closed;
6,AC/DC priority modes can be set;
7,Generator restart single(Dry contact);
8,Three times peak power,strong loading capacity;
9,Over load,output short circuit protection.

Model No. |
PL20-1000 |
PL20-2000 |
PL20-3000 |
PL20-4000 |
PL20-5000 |
PL20-6000 |
PL20-8000 |
PL20-10000 |
PL20-12000 |
Nominal Power |
1000W |
2000W |
3000W |
4000W |
5000W |
6000W |
8000W |
10000W |
12000W |
AC Input |
Phase & waveform |
Single phase & Pure Sine Wave |
Voltage |
120VAC/230VAC |
230VAC |
Voltage Range |
85-130VAC for 120VAC,185-265VAC for 230vac |
185-265VAC for 230vac |
Frequency |
50Hz:41-54HZ or 60Hz:51-64HZ (auto sensing) |
AC Output |
Phase & waveform |
Single phase & Pure Sine Wave |
Voltage |
120VAC/230VAC |
230VAC |
Voltage Regulation |
±10%rms |
Frequency |
60HZ/50HZ±0.3Hz |
50HZ/60HZ±0.3Hz |
Peak Power |
3 times of rating power |
AC charger |
Norminal Charging Current |
20A/35A/50A/70A/90A (5 stages adjustable charging current) |
Over charge protection |
Bat.V≥15.5VDC for 12V battery,Bat.V≥31.0VDC for 24V battery,
Bat.V≥62.0VDC for 48V battery,beeps 0.5s every 1s & fault after 60s |
Three stage charging |
Boost CC (constant current stage)
Boost CV (constant voltage stage)
Float (constant voltage stage) |
Solar charge controller |
Rated charge cuurent |
40A or 60A |
Rated charge battery voltage type |
12v/24v/48v 40A ; 12v/24v 60A |
Max. PV open circuit array voltage |
12V for 40Vdc,24V for 55Vdc,48V for 110Vdc |
Charge mode |
MPPT |
Efficiency |
≥97% |
PV low voltage re-connect |
PV≥Bat.v=3V |
PV low voltage disconnect |
PV≤Bat.v |
Battery voltage |
Norminal DC input Voltage |
12v/24v |
24v/48v |
48v |
Minimum Start Voltage |
10V for 12V, 20V for 24V, 40V for 48V |
DC input voltage range |
10.5VDC±0.3VDC ~ 16VDC±0.3VDC for 12V |
20VDC±0.6VDC ~ 32VDC±0.6VDC for 24V |
42VDC±1.2VDC ~ 164VDC±1.2VDC for 48V |
Transfer Efficiency |
Line Mode |
>95% |
Battery Mode |
>88% |
Transfer time |
AC to DC |
20ms(max) |
DC to AC |
15ms(max) |
System parameter |
Protections |
Low battery voltage,over charging,over load,over temp |
Over load protection |
110%<load<150%,beeps 0.5s every 1s,and fault after 60s off the output;
Load>150%,beeps 0.5s every 1s, and fault after 20s. |
Output short circuit protection |
current limit (fault after 10s) |
Surge rating(10s) |
1:3(VA) |
Power saver |
Load 25W(Enabled on "P/S auto" setting of remote control ) |
Indicators |
LED&LCD display |
General specifications |
Operating Temperature |
0℃ to 40℃ |
Storage temperature |
-15℃ to 60℃ |
Opration humidity |
5% to 95% (non condensing) |
Audible Noise |
≤60dB |
Cooling |
Forced air,Variable speed fan |
* Product specifications are subject to change without further notice