PL18 2kw inverter 12v 220v
Product Description
- LCD digital display show voltage, load and battery information in real time.
- Peak power is three times of rated power.
- Can work with inductive load such as air conditioner, motor door and so on.
- Pure sine wave output, available for sensitive load.
- 4-step progressive charging, 7 battery type selector.
- Fast and powerful charger with 35A and 70A/90A.
- Accept generator’s energy output.
- High power factor 0.9, low power consumption.
- Automatically transfer between battery and line modes.
- Microprocessor control guarantees high reliability.
- Remote control function.
- Protection against: Over load, over temperature, over charging, low battery



Model No. |
PL18-
1000
|
PL18-
1500
|
PL18-2000 |
PL18-3000 |
PL18-
4000
|
PL18-
5000
|
PL18-
6000
|
Nominal Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
6000W |
AC Input |
Phase & waveform |
Single phase & Pure Sine Wave |
Voltage |
110/120/130VAC OR 220/230/240VAC |
Acceptable Voltage |
95-126VAC OR 194-253VAC±4% |
Line Low Transfer |
85VAC±4% OR 184VAC ±4% |
Line Low Return |
95VAC±4% OR 194VAC ±4% |
Line high Transfer |
136VAC±4%/263VAC±4% |
Line high Return |
126VAC±4%/253VAC±4% |
Frequency |
50Hz:41-54Hz or 60Hz:51-64Hz (auto) |
Output |
waveform |
Pure Sine Wave |
Voltage |
110/120/130VAC OR 220/230/240VAC±10%rms
(bypass mode sync to input)
|
Frequency |
50Hz/60Hz±0.3Hz (bypass mode sync to input) |
Peak Power |
3 times of rating power |
Power Factor |
0.9-1.0 |
DC Input |
Battery Voltage |
12VDC OR 24VDC OR 48VDC |
Minimum Start Voltage |
10V for 12V, 20V for 24V, 40V for 48V |
Low Battery Alarm |
10.5V for 12V, 21V for 24V, 42V for 48V |
Low Battery Transfer |
10V for 12V, 20V for 24V, 40V for 48V |
High Voltage Alarm |
16V for 12V, 32V for 24V, 64V for 48V |
Max Charging Current |
20A/35A/50A/75A/90A(According to the inverter model) |
Transfer Efficiency |
Line Mode |
>96% |
Battery Mode |
>85% |
System Parameter |
power saver |
load≤25 Watts(Enabled on "P/S auto"setting of Remote control) |
Audible Alarm |
Sounding when the heat sink's tem is over 105℃
and shutdown after 30 seconds.
|
Over load Protections |
110%<load<150%,beeps 0.5s every 1s,and fault after 60s.
Load>150%,beeps 0.5s every 1s,and Fault after 20s
|
Protections |
low battery,over charging,over temp,over load |
Communications |
RS-232/USB/SNMP(custom-made) |
Environmental |
Operating Environment |
0-40℃,0-90%RH(non-condensing) |
Audible Noise |
<60dB |
Physical |
Net Weight(KG) |
15 |
17.5 |
19.5 |
25 |
35.5 |
39 |
47.5 |
Dimension(L*W*H) |
470*223*185 mm |
650*223*185 mm |