Input
|
|
DC input voltage range
|
24VDC:21-30VDC 48VDC:42-60VDC 96VDC:84-120VDC
|
Mains input voltage range
|
AC220V:170-270VAC
|
Mains input frequency range
|
45-65HZ
|
Protection
|
|
Battery low voltage alarm
|
24VDC:21V 48VDC:42V 96VDC:84V
|
Battery low voltage protection
|
24VDC:20V 48VDC:40V 96VDC:80V
|
Battery over voltage protection
|
24VDC:33.4V 48VDC:66.8V 96VDC:133.6V
|
Battery over voltage alarm
|
24VDC:30V 48VDC:60V 96VDC:120V
|
Over power protection
|
110% more than rated capacity
|
Temperature protection
|
≥85℃ alarm ≥90℃ machine shut off
|
Output
|
|
Efficiency
|
≥85%
|
Efficiency
|
≥85%
|
Output voltage (battery mode)
|
220VAC±2%
|
Output frequency (battery mode)
|
50/60HZ±1%
|
Output wave form
|
pure sine wave
|
Output voltage range (mains mode)
|
Stabilization output:220VAC±10%
|
Thermal method
|
Cooling fan in intelligent control
|
≤42℃ fan rotates slowly to ≥45℃ fan rotates fast
|
Working mode P1
|
Mains Priority mode(default working mode)
|
Mains priority mode with AC charging
|
Working mode P2
|
Energy saving mode
|
Load power≤10% machine turns off, ≥11%-100% machine turns on
|
Working mode P3
|
Solar power priority( Solar power priority without AC charging)
|
When charging: Battery voltage≥13V, turn converting mode;when converting: Battery voltage≤10.5V, turn mains mode.
|